Name | Type | Posted | Actions |
|---|---|---|---|
W912QR25R0016_CERT_Final_Specs-0009.pdf | Oct 2, 2025 | ||
W912QR25R0016_CERT_Final__Plans-0009.pdf | Oct 2, 2025 | ||
W912QR25R0016_CERT_Final__V3_CTWSTR_Plans-0008.pdf | Sep 11, 2025 | ||
W912QR25R0016_CERT_Final_V1A_OTW_Plans-0008.pdf | Sep 11, 2025 | ||
W912QR25R0016_CERT_Final_V1B_OTW_Plans-0008.pdf | Sep 11, 2025 | ||
W912QR25R0016_CERT_Final_Specs-0008.pdf | Sep 11, 2025 | ||
W912QR25R0016_CERT_Final_Specs-0007.pdf | Jul 1, 2025 | ||
W912QR25R0016-0006.pdf | Apr 14, 2025 | ||
W912QR25R0016_CERT_Final_EnviroAssess-0005.pdf | Apr 9, 2025 | ||
W912QR25R0016_CERT_Final_Plans-0005.pdf | Apr 9, 2025 | ||
W912QR25R0016_CERT_Final_Specs-0005.pdf | Apr 9, 2025 | ||
W912QR25R0016_CERT_Final_Specs-0004.pdf | Mar 28, 2025 | ||
W912QR25R0016_CERT_Final_Plans-0004.pdf | Mar 28, 2025 | ||
W912QR25R0016_CERT_Final_Specs-0003.pdf | Mar 6, 2025 | ||
W912QR25R0016_CERT_Final_Plans-0003.pdf | Mar 6, 2025 | ||
W912QR25R0016_CERT_Final_Vol5_ MFR_ConcreteMatTest-0003.pdf | Mar 6, 2025 | ||
Site Visit Sign In Sheet.docx | DOCX | Feb 19, 2025 | |
W912QR25R0016_CERT_Final_Specs-0002.pdf | Feb 14, 2025 | ||
Virtual Registration.pdf | Feb 10, 2025 | ||
W912QR25R0016 0001.pdf | Jan 23, 2025 | ||
W912QR25R0016_CERT_Final_Specs-0001.pdf | Jan 23, 2025 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_19of28_C-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_20of28_D1-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_21of28_D2-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_22of28_D3-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_23of28_D4-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_24of28_D5-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_25of28_D6-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_26of28_D7-000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_27of28_D8-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_28of28_E-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_1of20-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_2of20_A-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_3of20_B1-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_4of20_B2-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_5of20_B3-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_6of20_B4-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_7of20_B5-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_8of20_C1-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_9of20_C2-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_10of20_C3-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_11of20_C4-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_12of20_C5-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_13of20_D1-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_14of20_D2-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_15of20_D3-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_16of20_D4-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_17of20_E1-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_18of20_E2-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_19of20_E3-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillFMCR_20of20_E4-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillGroutCCR_1of9-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillGroutCCR_2of9_2A-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillGroutCCR_3of9_2B-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillGroutCCR_4of9_2C-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillGroutCCR_5of9_3-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillGroutCCR_6of9_4A-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillGroutCCR_7of9_4B-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillGroutCCR_8of9_4C-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_DrillGroutCCR_9of9_5-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_UpstreamBoringLog-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_ VerificationBoringLog-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_1of16-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_2of16_A-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_3of16_B1-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_4of16_B2-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_5of16_B3-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_6of16_B4-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_7of16_B5-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_8of16_B6-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_9aof16_C1a-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_10aof16_C2a-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_10bof16_C2b-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_11of16_D-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_12of16_E-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_13of16_F-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_14of16_G-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_15of16_H-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_16of16_I-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_1941_GeoReport-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_1953_DesignMemo1-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_1953_DesignMemo2-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_1956_DesignMemo3-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_Dam_AsBuilts-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ PH1B_ DownstreamBoringLog-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_V4c_Specs-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_Specs_01_31_00_Attachment-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_Specs_JIMP-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGBR_Appendix_A-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGBR_MainReport-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_1of28_MainReport-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_2of28_A1-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_10of28_A9-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol6_ ProjGIR_9bof16_C1b-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final__V1A_OTW_Plans-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final__V1B_OTW_Plans-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final__V2_OTW_Plans-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final__V3_CTWSTR_Plans-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_V4a_Specs-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_V4b_Specs-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_3of28_A2-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_4of28_A3-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_5of28_A4-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_6of28_A5-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_7of28_A6-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_8of28_A7-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_9of28_A8-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_11of28_A10-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_12of28_A11-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_13of28_A12-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_14of28_A13-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_15of28_B1-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_17of28_B3-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_18of28_B4-0000.pdf | Dec 21, 2024 | ||
W912QR25R0016_CERT_Final_Vol5_TunnelGDR_16of28_B2-0000.pdf | Dec 21, 2024 | ||
https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf | LINK | Dec 20, 2024 | |
https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?solNo=W912QR25R0016 | LINK | Dec 20, 2024 | |
https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml | LINK | Dec 20, 2024 | |
https://dodprocurementtoolbox.com/ | LINK | Dec 20, 2024 |
ROUGH RIVER DAM SAFETY MODIFICATION PHASE II: NEW OUTLET WORKS AND CUTOFF WALL PROJECT
Contact and place of performance
Adyson Medley
Falls of Rough, KY 40119
USA
ROUGH RIVER DAM SAFETY MODIFICATION PHASE II: NEW OUTLET WORKS AND CUTOFF WALLPROJECTThe contractor?s work and responsibility will include all planning, programming, administration, management,supervision, communications and inspection necessary to assure that all work is conducted in accordance with thecontract requirements and all applicable Federal, State and Local laws and regulations. All work will be performed...
View moreQuotes are due on 23 October 2025 at 10:00 AM Eastern Standard Time
You may submit your quote following the PIEE instructions below. Fax submittals will not be accepted.For contractual questions, please follow the ProjNET instruction above.
North American Industry Classification System (NAICS) 237990 This NAICS code shall be listed on the contractor?s SAM account prior to submitting a quote/proposal/bid.All contractors must be registered in the System for Award Management (www.SAM.gov) prior to submission ofquote. All proposed contractors are highly encouraged to review FAR Clause 52.232-33 Payments by ElectronicFunds Transfer ? System for Award Management, which indicates ?All payments by the Government under thiscontract shall be made by electronic funds transfer (EFT).? Those not currently registered can obtain registration bygoing to the website http://www.SAM.gov.Training tools are available on the SAM website to help you get familiar with SAM. Start by going towww.sam.gov, and then click on the SAM HELP tab. Under User Help you will find the full User Guide as well asQuick Start Guides and Helpful Hints that will help you create an account, migrate your roles, perform updates ,and search for the information you need. These guides can also be viewed at http://www.acquisition.gov.PLEASE NOTE: SAM is completely free of charge for both registrants and users.
The Department of the Army, U.S. Army Corps of Engineers Louisville District, is soliciting proposals for the Rough River Dam Safety Modification Phase II project in Falls of Rough, Kentucky. This requirement involves the construction of a new outlet works and a cutoff wall, classified under NAICS 237990 for Other Heavy and Civil Engineering Construction and PSC Y1KA for Construction of Dams. The contractor is responsible for all planning, administration, management, and supervision necessary to ensure all work complies with federal, state, and local regulations. The project documentation includes 115 attachments consisting of final specifications and multiple volumes of plans for the cutoff wall and outlet works.
This is a full and open procurement that incorporates a HUBZone 10% price evaluation preference. The government intends to award a single firm-fixed-price contract based on a total evaluated price determined by a price breakout schedule. Large business offerors are required to submit a subcontracting plan as part of their proposal. All payments under the resulting contract will be made via electronic funds transfer.
Proposals must be submitted through the Procurement Integrated Enterprise Environment (PIEE) by October 23, 2025, at 10:00 AM Eastern Standard Time. Offerors must be registered in the System for Award Management (SAM) with the applicable NAICS code prior to submission. Adyson Medley serves as the primary point of contact for solicitation W912QR25R0016, and technical inquiries are directed through the ProjNet system.
Generated by Lumen AI
Scoped analysis and attachments—go beyond the summary when you need detail from the solicitation package.