Name | Type | Posted | Actions |
|---|---|---|---|
70Z08525RLREP0003 Amendment 0003.pdf | Mar 19, 2025 | ||
70Z08525RLREP00030002.pdf | Mar 18, 2025 | ||
70Z08525RLREP00030001.pdf | Mar 11, 2025 | ||
Attachment A - USCGC STONE (WMSL-758) Specs REV1.pdf | Mar 11, 2025 | ||
Attachment B - Pricing Schedule USCGC STONE (WMSL-758).xls | XLS | Mar 4, 2025 | |
Attachment C - Request for Clarification USCGC STONE (WMSL-758).docx | DOCX | Mar 4, 2025 | |
Attachment D - HSAM Appendix G Dockside Availabilities USCGC STONE (WMSL-758).pdf | Mar 4, 2025 | ||
Attachment E - Past Performance Questionnaire (PPQ) USCGC STONE (WMSL-758).docx | DOCX | Mar 4, 2025 | |
Attachment F - Cutter Work Hours_USCGC STONE (WMSL-758).pdf | Mar 4, 2025 | ||
70Z08525RLREP0003 Solicitation Final.pdf | Mar 4, 2025 | ||
Attachment H - Standard WMSL Ship Check Instructions_USCGC STONE (WMSL-758).pdf | Mar 4, 2025 | ||
Attachment A - USCGC STONE (WMSL-758) Specs.pdf | Mar 4, 2025 | ||
Attachment G - FLETC Base Access and Pier Lay Down USCGC STONE (WMSL-758).pdf | Mar 4, 2025 | ||
Attachment I - Non-Disclosure Agreement USCGC STONE (WMSL-758).pdf | Mar 4, 2025 |
Dockside: USCGC STONE DS FY25 FQ3
Contact and place of performance
Richard Rawlings
North Charleston, South Carolina 29405
UNITED STATES
This requirement is for the Contractor to provide all necessary labor, services, supplies, materials, equipment power, accessories, personnel, and other things as necessary, except otherwise specified to perform dockside repairs to the USCGC STONE (WMSL-758), a 418-foot National Security Cutter in accordance with the solicitation, schedule, and specifications. Work includes, but is not limited to the following: WORK...
View moreThe United States Coast Guard has issued solicitation 70Z08525RLREP0003 for dockside repairs to the USCGC STONE (WMSL-758), a 418-foot National Security Cutter. The contractor must provide all labor, services, supplies, materials, equipment, and personnel necessary to execute the maintenance in North Charleston, South Carolina. Work items include grooming air conditioning, refrigeration, and reverse osmosis plants; testing cargo handling elevators, circuit breakers, and fire detection systems; and performing biennial maintenance on folding boom cranes. The scope also involves five-year certifications for miscellaneous system relief valves and the renewal of VCHT pump discharge check valves.
The project includes cleaning and inspecting various tanks, including those for aviation fuel, ballast, high purity water, potable water, grey water, and sewage. Optional work items cover the full or partial preservation of JP-5, ballast, and sewage holding tanks. The contractor is responsible for providing temporary services and fire prevention for the cutter during the performance period. This requirement is classified under NAICS 336611 for Ship Building and Repairing and PSC J998 for Non-Nuclear Ship Repair (East).
Responses to this solicitation are due by March 20, 2025. The administrative record for this notice includes 14 attachments, featuring multiple amendments, a pricing schedule, specifications, and a request for clarification form. Richard Rawlings serves as the point of contact for this requirement.
Generated by Lumen AI
Scoped analysis and attachments—go beyond the summary when you need detail from the solicitation package.